Full-Height Privacy

Full-Height Toilet Partitions

Tall doors, transoms, and Zero Sightline edges close the floor, ceiling, and door gaps of a standard stall.

Headrail-braced woodgrain flat-panel toilet partitions beside light tiled walls and flooring.

At a Glance

What Full-Height Privacy Needs

Full-height toilet partitions reduce the gaps a standard stall leaves at the floor, above the door, and along the door edges. Ironwood builds them with Floor to Ceiling or Headrail Braced mounting, an 84″ or taller door, Zero Sightline edges, and a transom where the door stops short of the ceiling.

Mounting
Floor to Ceiling or Headrail Braced
Door height
84″ default, up to 108″ by material
Floor clearance
0.5″ AFF with L brackets or recessed pedestals
Door edges
Zero Sightline

The Problem

The Gaps a Standard Stall Leaves

A hotel restroom with broad open space above the woodgrain partition doors and visible gaps beneath them.
  1. A standard stall leaves 12″ at the floor and stops near 70″.

    Full-height doors sit as low as 0.5″ above the floor and run up to 108″.Floor to Ceiling mounting

  2. Square door edges leave a line of sight into the stall.

    Zero Sightline laps the door and pilaster edges to close it.Zero Sightline

  3. Most ceilings sit higher than the tallest door.

    A transom covers the height between the door and the ceiling.Heights by material

Heights and Hardware

Maximum Door and Panel Heights by Material

Select a material to see its door and panel limits and the height a transom covers.

Material
High Pressure Laminate full-height stall: 108″ door from 0.5″ above the floor, pilaster connected to the example ceiling at 120″ AFF, transom to the ceiling, beside a standard stall with a 58″ door on a 12″ gap. Example ceiling · 120″ AFF102″ FTCflex threshold58″ door12″ gap70″ AFFStandard stall120″ maxtransom108″ door0.5″ AFFFull heightHigh Pressure Laminate

Door Pilaster Transom Standard stall

Max door
108″
Max panel
120″
Max pilaster
120″
Floor clearance
0.5″ AFF with L brackets (standard stall 12″)
Above the door
Transom to the ceiling
Door
The tallest single door Ironwood makes, with the widest pattern selection.
Hardware
Doors over 100 lb require a closer, which mounts to a headrail or transom.
Maximum component heights by material.
MaterialMax doorMax panelMax pilaster
High Pressure Laminate108″120″120″
Wood Veneer108″120″120″
Compact Laminate84″120″120″
Solid Surface96″96″120″
Engineered StoneNo stone doors96″120″

A door below 9″ AFF removes the toe clearance ADA Section 604.8.1.4 requires in an adult wheelchair compartment, so that compartment must be larger.

Pilasters over 120″ need special approval. Floor to Ceiling pilasters over 102″ may flex without perpendicular support. Door style, hardware, and ceiling height may set lower limits.

The Process

How to Specify Ironwood

A complete Ironwood specification in three steps.

  1. Open the Spec Builder

    A few guided choices turn your design intent into an exact Ironwood model number.

  2. Download Your Spec Package

    A CSI spec, cut sheet, and technical data are generated instantly for your exact model.

  3. Send It or Ask Us Anything

    Call 360-568-1823 or email specs@ironwood-mfg.com. Our specialists walk projects end-to-end.

What You Walk Away With

  • CSI Spec
  • Cut Sheet
  • Technical Data

Questions

Full-Height Partition Questions

Designer presenting partition plans to a seated project team

Not finding the answer? Reach out and a specialist will help.

Contact Us
  • A full-height toilet partition, also called a no-gap or high-privacy bathroom stall, uses taller doors and panels to reduce the gaps at the floor and ceiling. A standard stall typically leaves 12″ at the floor and stops near 70″. Zero Sightline construction removes the straight-through gap at the door edges.
  • Full height describes the privacy build, with taller doors and panels and smaller gaps. Floor to Ceiling is a mounting style that anchors pilasters at the floor and the ceiling. A full-height build can also use Headrail Braced mounting, and a Floor-to-Ceiling partition can have standard-height doors.
  • High Pressure Laminate and Wood Veneer doors reach 108″, Solid Surface doors reach 96″, and Compact Laminate doors reach 84″. Ironwood does not make Engineered Stone doors, so stone projects use another material, typically Wood Veneer, which reaches the full 108″ door height. Door style, hardware, and ceiling height may set a lower limit.
  • Floor to Ceiling and Headrail Braced. Floor to Ceiling is preferred for full-height work and needs a hard-lid ceiling with structural backing. Ceiling plates cannot attach to suspended acoustic ceiling tile, so Headrail Braced is the alternative where the ceiling is unsuitable.
  • With a transom, a horizontal component mounted above the door between the pilasters. It covers the height the door cannot reach and gives a door closer a place to mount when there is no headrail. Transoms may affect fire and lighting code compliance, so confirm them against the adopted code.

  • Doors over 100 lb require a closer, which mounts to a headrail or transom. Solid Surface doors from 71″ to 96″ require continuous geared hinges and an overhead closer. Continuous hinges keep the hinge edge flat, so Zero Sightline laps only the strike edge. The hinge guide compares the options.
  • Yes, in a compartment sized for it. ADA Section 604.8.1.4 requires 9″ of toe clearance below the front partition and one side partition of an adult wheelchair compartment. Without front clearance, the compartment must be deeper than 62″ with a wall-hung water closet or 65″ with a floor-mounted one. Without side clearance, it must be wider than 66″. Confirm the adopted code for each project.

  • Typically, yes. Zero Sightline carries a higher cost than Flat Edge, and Floor to Ceiling costs more than Headrail Braced. Door height, material, and hardware also affect the price, so a quote request gives the project figure.
  • Ceiling backing, lighting, and delivery. Floor-to-Ceiling backing must be in place before the ceiling closes, and the ceiling height is measured at each pilaster. Smaller gaps reduce ambient light in the stall, so compartment lighting is coordinated with the lighting design. Oversized components also need clear delivery and handling paths.

Next Steps

Start a Full-Height Project

  • Build Your Spec

    Configure an 84″ Floor-to-Ceiling build with Zero Sightline edges. Change the material, door style, or hardware as needed.

  • Request a Quote

    For doors over 84″, transoms, Solid Surface, or Engineered Stone, send reflected ceiling plans, elevations, and door schedules.

  • Request Samples

    Compare finishes for doors, panels, and transoms.