Full-Height Privacy
Full-Height Toilet Partitions
Tall doors, transoms, and Zero Sightline edges close the floor, ceiling, and door gaps of a standard stall.

At a Glance
What Full-Height Privacy Needs
Full-height toilet partitions reduce the gaps a standard stall leaves at the floor, above the door, and along the door edges. Ironwood builds them with Floor to Ceiling or Headrail Braced mounting, an 84″ or taller door, Zero Sightline edges, and a transom where the door stops short of the ceiling.
- Mounting
- Floor to Ceiling or Headrail Braced
- Door height
- 84″ default, up to 108″ by material
- Floor clearance
- 0.5″ AFF with L brackets or recessed pedestals
- Door edges
- Zero Sightline
Installed Proof
Featured Full-Height Installations
Flat Panel · High Pressure Laminate · Floor to Ceiling
Flat Panel · High Pressure Laminate · Floor to Ceiling
Flat Panel · Wood Veneer · Floor to Ceiling
Flat Panel · Compact Laminate · Floor to Ceiling
Captured Panel · Compact Laminate · Floor to Ceiling
Flat Panel · High Pressure Laminate · Headrail Braced
The Problem
The Gaps a Standard Stall Leaves

A standard stall leaves 12″ at the floor and stops near 70″.
Full-height doors sit as low as 0.5″ above the floor and run up to 108″.Floor to Ceiling mounting
Square door edges leave a line of sight into the stall.
Zero Sightline laps the door and pilaster edges to close it.Zero Sightline
Most ceilings sit higher than the tallest door.
A transom covers the height between the door and the ceiling.Heights by material
Recommended Build
What Works with Full-Height Privacy
Every option below suits a full-height build. The recommended choice comes first on each tab.
Heights and Hardware
Maximum Door and Panel Heights by Material
Select a material to see its door and panel limits and the height a transom covers.
Door Pilaster Transom Standard stall
- Material
- High Pressure Laminate
- Max door
- 108″
- Max panel
- 120″
- Max pilaster
- 120″
- Floor clearance
- 0.5″ AFF with L brackets (standard stall 12″)
- Above the door
- Transom to the ceiling
- Door
- The tallest single door Ironwood makes, with the widest pattern selection.
- Hardware
- Doors over 100 lb require a closer, which mounts to a headrail or transom.
- Material
- Wood Veneer
- Max door
- 108″
- Max panel
- 120″
- Max pilaster
- 120″
- Floor clearance
- 0.5″ AFF with L brackets (standard stall 12″)
- Above the door
- Transom to the ceiling
- Door
- Reaches the same 108″ door as HPL with a real wood face.
- Hardware
- Doors over 100 lb require a closer, which mounts to a headrail or transom.
- Material
- Compact Laminate
- Max door
- 84″
- Max panel
- 120″
- Max pilaster
- 120″
- Floor clearance
- 0.5″ AFF with L brackets (standard stall 12″)
- Above the door
- Transom to the ceiling
- Door
- A solid phenolic core. The door stops at 84″, so the transom covers more height.
- Hardware
- Doors over 100 lb require a closer, which mounts to a headrail or transom.
- Material
- Solid Surface
- Max door
- 96″
- Max panel
- 96″
- Max pilaster
- 120″
- Floor clearance
- 0.5″ AFF with L brackets (standard stall 12″)
- Above the door
- Transom to the ceiling
- Door
- A seamless, non-porous face. Doors from 59″ to 70″ are not available.
- Hardware
- Doors from 71″ to 96″ require a continuous geared hinge and an overhead closer.
- Material
- Engineered Stone
- Max door
- No stone doors
- Max panel
- 96″
- Max pilaster
- 120″
- Floor clearance
- 0.5″ AFF with L brackets (standard stall 12″)
- Above the door
- Transom to the ceiling
- Door
- No stone doors. Panels reach 96″ and pilasters 120″; the door comes in another material, typically Wood Veneer.
- Hardware
- Hardware follows the door material.
| Material | Max door | Max panel | Max pilaster |
|---|---|---|---|
| High Pressure Laminate | 108″ | 120″ | 120″ |
| Wood Veneer | 108″ | 120″ | 120″ |
| Compact Laminate | 84″ | 120″ | 120″ |
| Solid Surface | 96″ | 96″ | 120″ |
| Engineered Stone | No stone doors | 96″ | 120″ |
A door below 9″ AFF removes the toe clearance ADA Section 604.8.1.4 requires in an adult wheelchair compartment, so that compartment must be larger.
Pilasters over 120″ need special approval. Floor to Ceiling pilasters over 102″ may flex without perpendicular support. Door style, hardware, and ceiling height may set lower limits.
The Process
How to Specify Ironwood
A complete Ironwood specification in three steps.
Open the Spec Builder
A few guided choices turn your design intent into an exact Ironwood model number.
Download Your Spec Package
A CSI spec, cut sheet, and technical data are generated instantly for your exact model.
Send It or Ask Us Anything
Call 360-568-1823 or email specs@ironwood-mfg.com. Our specialists walk projects end-to-end.
What You Walk Away With
- CSI Spec
- Cut Sheet
- Technical Data
Questions
Full-Height Partition Questions
- A full-height toilet partition, also called a no-gap or high-privacy bathroom stall, uses taller doors and panels to reduce the gaps at the floor and ceiling. A standard stall typically leaves 12″ at the floor and stops near 70″. Zero Sightline construction removes the straight-through gap at the door edges.
- Full height describes the privacy build, with taller doors and panels and smaller gaps. Floor to Ceiling is a mounting style that anchors pilasters at the floor and the ceiling. A full-height build can also use Headrail Braced mounting, and a Floor-to-Ceiling partition can have standard-height doors.
- High Pressure Laminate and Wood Veneer doors reach 108″, Solid Surface doors reach 96″, and Compact Laminate doors reach 84″. Ironwood does not make Engineered Stone doors, so stone projects use another material, typically Wood Veneer, which reaches the full 108″ door height. Door style, hardware, and ceiling height may set a lower limit.
- Floor to Ceiling and Headrail Braced. Floor to Ceiling is preferred for full-height work and needs a hard-lid ceiling with structural backing. Ceiling plates cannot attach to suspended acoustic ceiling tile, so Headrail Braced is the alternative where the ceiling is unsuitable.
With a transom, a horizontal component mounted above the door between the pilasters. It covers the height the door cannot reach and gives a door closer a place to mount when there is no headrail. Transoms may affect fire and lighting code compliance, so confirm them against the adopted code.
- Doors over 100 lb require a closer, which mounts to a headrail or transom. Solid Surface doors from 71″ to 96″ require continuous geared hinges and an overhead closer. Continuous hinges keep the hinge edge flat, so Zero Sightline laps only the strike edge. The hinge guide compares the options.
Yes, in a compartment sized for it. ADA Section 604.8.1.4 requires 9″ of toe clearance below the front partition and one side partition of an adult wheelchair compartment. Without front clearance, the compartment must be deeper than 62″ with a wall-hung water closet or 65″ with a floor-mounted one. Without side clearance, it must be wider than 66″. Confirm the adopted code for each project.
- Typically, yes. Zero Sightline carries a higher cost than Flat Edge, and Floor to Ceiling costs more than Headrail Braced. Door height, material, and hardware also affect the price, so a quote request gives the project figure.
Ceiling backing, lighting, and delivery. Floor-to-Ceiling backing must be in place before the ceiling closes, and the ceiling height is measured at each pilaster. Smaller gaps reduce ambient light in the stall, so compartment lighting is coordinated with the lighting design. Oversized components also need clear delivery and handling paths.
Next Steps
Start a Full-Height Project
Build Your Spec
Configure an 84″ Floor-to-Ceiling build with Zero Sightline edges. Change the material, door style, or hardware as needed.
Request a Quote
For doors over 84″, transoms, Solid Surface, or Engineered Stone, send reflected ceiling plans, elevations, and door schedules.
Request Samples
Compare finishes for doors, panels, and transoms.